Upload your lab report.Get your classification.
Traditional waste classification takes days. VeriClass reads your ALS or Eurofins lab report, applies the NSW EPA guidelines with deterministic logic, and prepares a professional report. Every report is reviewed and signed by a qualified environmental scientist.
Built for the infrastructure & construction industry — excavation, remediation and heavy-haulage teams across NSW. General · Restricted · Hazardous · Special Waste (asbestos).
Accurate classification in minutes, not days.
Speed and accuracy are the whole point. VeriClass collapses a slow, manual consultant process into a few minutes, without giving up rigour or sign-off.
Traditional classification means waiting days — sometimes weeks — for a consultant to interpret lab data by hand. VeriClass returns a signed report while you're still on site.
The NSW EPA logic is deterministic code, and every extracted value is verified verbatim against the source certificate. The thresholds decide — identically, every time.
Every report is reviewed and signed off by an accredited environmental scientist before you rely on it for transport or disposal. AI speed, human accountability.
From lab report to classification in three steps
Upload & describe
Drop your ALS or Eurofins lab report PDF, add the site address, a short material description, and any site photos. Answer six quick NSW EPA screening questions.
AI extracts, NSW EPA logic classifies
VeriClass reads the contaminant tables with AI, verifies every value against the source, then runs the deterministic NSW EPA 6-step process — CT1/CT2, SCC and TCLP thresholds.
Get a signed report
A professional, colour-coded PDF with the classification outcome, full results matrix, site map and disposal guidance — signed off by an environmental scientist, then viewable on screen, downloadable, or emailed.
Built for decisions that carry regulatory weight
Based on the NSW EPA Guidelines
Follows the steps of the NSW EPA Waste Classification Guidelines (2014): special waste, pre-classified waste, hazardous characteristics, the chemical assessment and putrescibility.
Deterministic, not guessed
Classification is rule-based code, never AI. The model only reads the document; the NSW EPA thresholds decide the outcome — every time, identically.
Reviewed and signed
Every report is reviewed and signed by a qualified environmental scientist. A value VeriClass can't read with confidence is held for them to check, never hidden.
Professional reporting
Branded PDF with a colour-coded results matrix, the full 6-step table, a site location map and a reviewer signature block.
Audit trail
Every upload, classification, download and email is timestamped and recorded — the traceability a compliance workflow demands.
A result your client can trust at a glance
Concentrations are compared against CT1 (general) and CT2 (restricted) thresholds and colour-coded the moment they land. Each sample gets its own class from its worst contaminant, so you can see which material goes where.
- At or below CT1 — general solid waste
- Above CT1, at or below CT2 — restricted
- Above CT2 — hazardous
| Contaminant | Result | CT1 |
|---|---|---|
| Arsenic | < LOR | 100 |
| Lead | 7 | 100 |
| Nickel | 27 | 40 |
| C10–C36 TRH | 9,880 | 10,000 |
| Benzo(a)pyrene | < LOR | 0.8 |
AI-assisted. Every report is reviewed and signed by a qualified environmental scientist.
Move a contaminant. Watch the class change.
Drag any concentration across its CT1 and CT2 thresholds. The result is rule-based, not guessed: the single worst analyte governs the sample, exactly as the NSW EPA guidelines require — and exactly what VeriClass computes from your real lab data.
Illustrative thresholds on a log axis, for demonstration only. Every VeriClass report is reviewed and signed off by a suitably qualified environmental scientist before it is issued.
The core tests, under the NSW EPA guidelines
Metals
Arsenic, cadmium, chromium, lead, mercury and nickel
Hydrocarbons and BTEX
Petroleum hydrocarbons C6–C9 and C10–C36; benzene, toluene, ethylbenzene and xylenes
PAHs
Benzo(a)pyrene and total PAHs
Asbestos
When the laboratory has tested for it
VeriClass assesses these core tests only. This classification uses the NSW EPA Waste Classification Guidelines Part 1 (2014) only, including for sites in other Australian states or territories. It does not assess pesticides, PCBs, PFAS, acid sulfate soil, liquid, flammable or corrosive waste, any lab result outside the contaminants listed, or whether the material can be reused. VeriClass does not currently issue VENM certificates.
Simple pricing that scales with you
Pay per report, or take up to 30 reports a month on the volume plan. Bulk discounts are available, and bigger programs get a tailored quote — no lock-in.
Per report
For one-off projects and occasional classifications.
- The core tests, under the NSW EPA Waste Classification Guidelines (2014)
- Report signed off by an environmental scientist
- Site map & colour-coded contaminant tables
- No subscription and no lock-in
Volume plan
For infrastructure and remediation programs with steady volume.
- Up to 30 reports per month (a A$471 saving)
- Report history, audit trail & quantities tracking
- Priority processing & email delivery
Custom
Bespoke volume, multi-team rollouts or integrations.
- Discounts available for bulk reports
- Volume & multi-team pricing
- Custom onboarding & training
- Roadmap input (new states, integrations)
Prices in AUD. Enterprise enquiries: contact@vericlass.io. Payments are processed securely by Stripe once your account is connected.
Classify your next lab report in minutes
Upload a laboratory certificate and get an NSW EPA classification, reviewed and signed off by an environmental scientist.
Sign up / Log in





